-40%

Rod-L M25 Ground Continuity Tester 25 Amps

$ 105.07

Availability: 100 in stock
  • Item must be returned within: 14 Days
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Condition: Used
  • Current Range: 25 A
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted

    Description

    Standard Description
    Description
    Rod-L M25 Ground Continuity Tester 25 Amps
    OVERVIEW
    ROD-L ground bond testers are designed to assess the electrical integrity of the safety ground paths between the exposed conductive surfaces of products and the earth pins of their AC power cords. By using our ground bond testers to continuously test for acceptable resistances in those paths as they are subjected to currents that are near the limit of what the overcurrent protection for their AC power mains will allow, our ground bond testers can test for electrical safety and integrity issues caused by marginal single-strand wiring or other problems that ordinary low current ground continuity testers may miss. Our model M25, M30, M35, and M40 ground bond testers are designed to test for acceptably low resistance at 25 amps, 30 amps, 35 amps, and 40 amps respectively. In addition, our ground bond testers are designed to perform these ground bond tests in compliance with UL, BSI,IEC, and other applicable electrical safety testing standards. These standards serve to help reduce your exposure to product liability claims and your risk of producing electrically unsafe products.
    FEATURES
    Triggers audible and visual alarms If the ground resistance exceeds the preset value
    Performs ground bond tests in full compliance with BSI, VDE, and IEC standards
    Test time is adjustable from 1 to 90 seconds
    Tests resistance (up to 0.15 Ohms) between the chassis of the tested product and the ground pin of its power cord
    Can connect to any ROD-L hipot tester to enable combination testing via a common start-click and tester connection
    AC power source supplies 25 Amps (user-specified) at about 2.5 volts
    Front panel receptacle is rated to 8000 VAC
    Reports test progress, test failures, the chassis ground resistance (0 - 0.15 Ohms), and the applied current
    Ground resistance trip point can be preset via a rear-panel potentiometer
    Input Power Required: 115/230 VAC, ± 10%, 44-66 Hz, 360 watts maximum
    Weight: 30 lbs Net
    This ground continuity test instrument can be interconnected to with any Rod-l Test instrument to form an automated test system or used as a stand alone instrument.
    Operating and Service Manual available http://www.nousnexus.com/Manuals/ROD-L_M10_M25_M30_M35_Operation_Service.pdf.
    The item is tested and working. No cables or leads are included. One of the side rails is cracked as shown in the photos.
    Shipping Weight (lbs.):
    36
    Shipping Dimensions (in.):
    25 x 21 x 13